Fig. 8.1 - 8.2 - 8.3
Warning!
The cooker hood is supplied with 4 side
spacers (2 for the right side and 2 for the left side), these
are useful when the width of the housing cabinet for the
cooker hood motor body is wider than 6mm.
In this instance the spacers should be mounted outside
the cooker hood body corresponding to the perforations for
the cabinet fixing screws. Z - Fig. 8.1-8.3
The hood must be fitted with a pipe having the same diameter
as the air outlet.
To mount the hood proceed as follows:
-
Position the drilling template inside the left cupboard on
the right hand side with the arrow point towards the back
on the cupboard.
-
Drill the holes marked on the template.
-
Repeat the procedure for the right hand cupboard
-
If the sides of the cupboards are 16 mm thick, insert 4
spacers Z on the sides of the hood.
-
Fix the hood to the cupboard using four screws N.
Fig. 8.3
Additional instructions for the montage
Box adjustement
The hood can be installed in cabinets with different depths,
the front of the box must always be in line with the cabinet.
For alignment adjust the back stops of the box. For box
adjustment, loosen screws "M" and slide square plates "G" as
necessary and tighten screws "M". Fig. 9

Operation

The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.

Maintenance

ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.

Cleaning

The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning
recommendations of the cooker hood and replacement of the
filters may cause fire risks.
Therefore, we recommend observing these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.

Grease filter

Traps cooking grease particles.
If situated inside the support grill, it may be one of the
following types:
Paper filter must be replaced once a month or if colouring
appears on upper side, in such cases the colouring is evident
through the grill openings.
Metallic filter must be cleaned once a month, with non
abrasive detergents,
temperature and short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
Removing the Grease Filters (for models wtih grease filter
support grates)
To remove the dirty grease filter, proceed as follows:
a.
Remove the pull-out drawer completely and open the
ventilation grates that support the grease filters.
b. Remove the Q fasteners for the grease filter and remove
it (Fig. 10.1). If special metal filters have been installed,
press on the plastic springs R to unhook them (Fig.
10.2).
c.
When washing or replacing the grease filter, wash the
grate as well with warm soapy water.
d. Remount the new filter or the old one after it has dried
thoroughly.

Charcoal filter (filter version only)

It absorbs unpleasant odours caused by cooking.
The saturation of the charcoal filter occurs after more or less
prolonged use, depending on the type of cooking and the
regularity of cleaning of the grease filter. In any case it is
necessary to replace the cartridge at least every four mounths
(or when the filter saturation indication system – if envisaged
on the model in possession – indicates this necessity).The
charcoal filter may NOT be washed or regenerated.
To fit or replace a carbon filter:
a.
Request a charcoal filter from the retailer, specifying the
model and type of hood.
Caution! Some charcoal filters come covered with a plastic
film to protect their filtering properties. If this is the case,
remove the film before installing the filter.
b. Remove the pull-out drawer completely.
c.
Remove the grease filters or the grates.
d. Place the activated carbon filter in position:
1)
Version with one motor: insert the filter in its housing
over the plastic grill and rotate it until it locks in
position (Fig. 6).
2)
Version with two motors: to assemble the filter,
insert it in its seating and fix it in position using the
clips L (Fig. 7)
e.
Remove the grease filters or grills
To remove the carbon filter, follow the procedure described in
item 1) or 2), depending on the version) in the reverse order.