Herunterladen Inhalt Inhalt Diese Seite drucken

TERMA TDY Gebrauchsanweisung Seite 19

Elektroheizkörper
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
Problem
Heating element is con-
nected to the mains but
no LEDs lights up.
Heating element does
not heat up. LEDs light
up alternately and
evenly
Heating element does
not heat up. LEDs light
up alternately and
unevenly
If the problem persists, contact your supplier.
EN
Possible cause
Problem solution
Check the cable for damages and if the
Mains
device is properly plugged in. Check the
connection.
plug and the socket.
Make sure the power output of the heat-
ing element does not exceed the rec-
ommended heating output of a radiator.
Check and reduce the temperature of the
Overheating
heating medium inside the central heating
installation (it cannot be higher than 82°C)
If the radiator is not connected to the cen-
tral heating installation, make sure it has
been properly filled with heating medium.
Damage to the
Disconnect the device from the power
temperature
supply, wait until it cools down, connect
sensor
the device back to the power supply.
19