Parts and their functions
Rear panel
 Camera cable connector [CAMERA]
(26-pin connector)
The camera's cable (such as the AW-CA50A26) is
connected here.
 Contact-type pan/tilt head control connector
[PAN/TILT CONTROL IN]
(D-SUB 15-pin connector)
 This has the same shape as the tally/intercom input/
output connector. Take care not to confuse the two
when connecting them.
A controller for controlling the lens (a lens with zoom
and focus servo) and pan/tilt head (up, down, left,
right, defroster, wiper, etc.) is connected here. (Only a
contact-type controller can be connected.)
Pin No.
Signal Name
1
2
3
4
DOWN
5
6
7
8
9
DEFROSTER
10
WIPER
11
COMM
12
13
+V (+7.5 V)
14
–V (+2.5 V)
15
 The optional board must be installed in the camera in
order to use a contact-type pan/tilt head. For details,
refer to the camera's operating instructions.
 When the control pins (#1 to #10) are connected to the
COMM pin (#11), the control signals are sent from the
RCU to the camera.
 When the controller is to be fabricated, connect a
resistor with a resistance of 1 to 10 kilohms (1/8 W or
more) between the COMM pin and +5 V pin.
LEFT
RIGHT
UP
FAR
NEAR
TELE
WIDE
+5 V
GND
 Ensure that both the LEFT and RIGHT pins are not
connected to the COMM pin at the same time.
 Similarly, do not connect both the UP and DOWN, FAR
and NEAR or WIDE and TELE pins to the COMM pin
at the same time.
 Pins #12 to #15 are used when exercising lens control
only. To do this, connect the controller's FOCUS CONT
pin to NEAR (pin #6) and its ZOOM CONT pin to WIDE
(pin #8). (Normally, pins #12 to #15 are not used when
exercising control by contacts.)
 Gen-lock input/output connector
[G/L IN/OUT]
(75-ohm automatic termination)
The external sync signals (black burst signals or
composite signals) from another system are connected
here.
Note:
The input signals must be connected to the BNC
connector marked "IN" (75-ohm automatic termination).
If it is connected to the BNC connector marked "OUT," a
high-impedance state will result, and the connector will
not be terminated by the 75-ohm resistance.
 AUX signal input/output connector
[AUX IN/OUT] (75-ohm automatic termination)
Connect the line view signals from a live switcher or other
device here.
Note:
The input signals must be connected to the BNC
connector marked "IN" (75-ohm automatic termination).
If it is connected to the BNC connector marked "OUT," a
high-impedance state will result, and the connector will
not be terminated by the 75-ohm resistance.