Operating voltage
Conductor cross-section flexible
Conductor cross-section rigid
A maximum of 1 conductor per clamp may be connected. Tighten the screws with a torque of
0.5Nm.
3.4.
Pin assignment P-Ex WLAN power supply (PoE) and data stream circuit
Pin assignment of the DC power supply circuit (power over ethernet): to LSA+ X10 module
clamp
LSA+ X10 module clamp -
Ex e
Operating voltage
Pin assignment of the data stream circuit to LSA+ module clamp: X11
LSA+ X11 module clamp –
Ex e
Operating voltage
Conductor cross-section rigid
A maximum of 1 conductor per clamp may be connected. The copper conductors are con-
nected with a standard LSA+ punch down tool. Tighten the safety catch with a torque of
1.2Nm.
+18V to +28V DC
2
-0.2 mm
– 1.3 mm
2
-0.2 mm
– 1.3 mm
Assignment
Clamps description
UB+
UB+
UB-
UB-
+18V to +28V DC
Assignment
Clamps description
Tx+
Tx-
Rx+
Rx-
5V (± 10%)
2
0.4mm
– 0.64mm
2
/ 24AWG – 16AWG
2
/ 24AWG – 16AWG
Clamps number
X10-4
X10-5
X10-7
X10-8
Clamps number
X11-1
X11-2
X11-3
X11-6
2
/ 26AWG – 22AWG
27