Advanced Gateway 2330 modules

Advanced Gateway 2330 module protection

The following practices prevent equipment damage when you work on the Avaya Advanced
Gateway 2330:
• Always wear a grounded antistatic wrist strap when you handle modules.
• Always set modules on appropriate antistatic material.
• Handle modules by the faceplate and handles. Do not touch pins or electrical connections.
• Do not leave interface module or power supply module slots empty. You must fill all slots
with modules or slot covers to maintain safety compliance, proper cooling, and
electromagnetic interference (EMI) containment in the shelf.
• Ensure that your environment meets the requirements for temperature, humidity, and
cleanliness.
• Do not overtighten thumb screws or lug nuts. Tighten screws and nuts until they are snug,
plus a quarter turn. If you use a power tool to tighten screws, use a low torque setting
of 2 to 3 in–lb (0.226 to 0.339 N-m).
Caution:
If you do not install interface modules in slots, keep the metal cover plates in place over the
slots. Removing the cover plates impedes airflow and proper cooling of the unit.
16
Regulatory Information
Plug standard
BS1363 male plug with fuse
AS3112-1981 male plug
Rating
220 or 230 VAC
50 Hz
Single phase
100 or 120 VAC
50-60 Hz
Single phase
240 VAC
50 Hz
Single phase
240 VAC
50 Hz
Single phase