! Depth of Drive Adjustment:
Keep the tool pointed in a safe direction.
Disconnect the tool from the air supply and remove all fasteners.
The depth of drive adjustment is made by adjusting the work
contacting element. The screw is loosened to allow the element to be
moved up or down. You will need a 4mm hex socket wrench to make
this adjustment.
If the tool is overdriving (the fastener head is driven below the work
surface), the work contacting element should be moved downward. if
the fasteners stand up (the head or crown is not flush with the work
surface), the work contacting element should be moved up.
Adjust the work contacting element until the fastener head or crown
depth meets job requirements.
WARNING
MOVE UP
TO INCREASE
DRIVE PEPTH
MOVE DOWN
TO DECREASE
DRIVE PEPTH
SOCKET
HEAD
CAP SCREW
WORK
CONTACTING
ELEMENT
-9-