Electrical connections

Power supply 230V (a.c.) 50/60 Hz
L-N
10-11 Terminals for powering 24V (a.c.) accessories
Open gate indicator-light (socket rating: 24V - 3W max.)
10-5
Flashing light (socket rating: 230V - 25W max.)
W-E
U-V-W Motor "1" single-phase 230V (a.c.) delayed opening
Adjustment Trimmer
Trimmer T.R.2M. = Adjusting the delay of gearmotor 2 from 1 minute to 10 seconds.
Trimmer T.C.A. = Adjusting automatic opening and closing times from 0 seconds to 120 seconds.
(Note: adjusting the trimmer to the maximum excludes the automatic closing function ).
Trimmer T.L.
= Adjusting the working time from 15 seconds to 120 seconds.
(Note: adjusting the working time to the minimum enables the maintained-action command
function ).
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
E
X-Y-W Motor "2" single-phase 230V (a.c.) delayed closure
2-C1 Re-open during closing (N.C.) socket
Stop button (N.C. socket)
1-2
Keyswitch and/or commands button (N.O.)
2-7
Connection of antenna