SECONDARY SPRAY APPLICATOR MAINTENANCE
TROUBLESHOOTING - BLOCKED NOZZLE OR CONTINUOUS
SPRAY WITHOUT PRESSING THE TRIGGER
STEP 1
Locate and unscrew retaining ring. To release; turn retaining ring in an
anti-clockwise motion.
STEP 2
Gently pull on the adjustable nozzle to remove.
STEP 3
Fit an 8mm spanner to the flat edges of the fluid nozzle and turn
anti-clockwise to unscrew
STEP 4
Ensure you do not misplace the o-ring seal, which is located behind the
fluid nozzle .
STEP 5
Once removed, visually inspect the fluid nozzle for small particles or
blockages - rinse thoroughly with hot water.
STEP 6
Gently wipe the fluid needle to clean and remove any debris (the fluid
needle should not be removed from the applicator at any time).
STEP 7
Once visually clear of any debris, re-attach fluid nozzle, ensuring the
O-ring is in position, then use the spanner (8mm) to gently tighten back
into place.
STEP 8
Replace adjustable nozzle and rotate back into position.
STEP 9
Repeat previous step, this time with the retaining ring.