TROUBLESHOOTING
If you are experiencing problems with this unit, in the first instance please carefully read
the relevant sections of the User Manual and the Troubleshooting section below. If you
cannot solve your problem please contact your supplier for further assistance.
PROBLEM
My solution is
bubbling from
the cup
The air flow is
cutting in an out
The Spray Unit
will not turn on
The spray
applicator is
leaking
My hose won't
screw into the
unit.
AUSTRALIA | CHINA | UNITED KINGDOM | USA
CAUSE
Seal is not in properly
Solution Cup is not screwed in
correctly
The cup is cross-threaded
Solution cup is overfilled
The filter is dirty
The power setting need
adjusting
Power cord not attached
Electricity not turned on
Spray Cup is not tight enough
Too much solution
Nozzle may be blocked
Prongs & groove are not
aligning properly
WHAT TO DO
Fit the gun seal correctly.
Unscrew and reattach the cup.
Unscrew and reattach the cup.
Empty some solution from the
cup so it is half to 3/4 full.
Remove the filter from the base of
the unit and rinse in warm water.
Wait until filter is completely dry
before refitting.
Increase the power on your system.
Ensure that the power cord is
pushed in firmly to the base of the
unit and wall socket
Ensure that the power point is on
Tighten the solution cup
Empty some solution from the
cup so it is half to 3/4 full
Perform secondary maintenance
Pull connection back exposing
the prongs. Ensuring the groove
is facing the top, line up the prongs
to meet the unit. Release the
connection & screw in clockwise.
www.tanningessentials.co