 Empty the container fully.
 Fold the container back into its original
position.
 Fold the container lock to the middle
and arrest it.
 Release parking brake.
General
– If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
– If the maximum liquid level is reached
the appliance will turn off automatically.
– In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
– After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-40/C-DN-40 accessories can
be connected.

Operation

Removing/inserting container
 Release and remove the suction head.
 Unhook the drain hose.
 Pull both sliders out.
 Remove the container toward the top.
 Install the container in reverse order.
Illustration
Note: Observe the illustration when install-
ing the container.
16
Turning on the Appliance
 Plug in the main plug.
 Switch on the appliance at the rotating
knob.
Working with electrical power tools
Illustration
 Adjust the tool adapter to fit the connec-
tion of the electric power tool.
Illustration
 Remove the elbow from the suction
hose.
 Attach the tool adapter to the suction
hose.
Illustration
 Connect the tool adapter to the electric
power tool.
Automatic filter cleaning
The appliance has an innovative dual filter
cleaning system that is particularly effective
with fine dust. The flat pleated filter is auto-
matically cleaned every 7.5 seconds
through an air jet (pulsating sound).
Turn off the appliance
 Switch off the appliance at the rotating
knob.
 Pull out the mains plug.
After each operation
 Empty the container.
 Vacuum and wipe the appliance inside
and outside with a damp cloth.
Fold the push handle in/out
 Loosen the fastening screws of the
pushing handle and adjust the pushing
handle.
– 3
EN
Rotating knob
– Appliance ON
– Filter dedusting OFF
– Appliance OFF
– Appliance ON
– Filter dedusting ON