While the pump is running, the screen displays the input signal value and its calculat-
ed equivalent actual flow rate.
Notice the pump status has changed to "Running".

3.3. Manual Mode

On the Run Modes Selection screen, select the "Manual" to be taken to the Manual
mode start screen.
To start the pump select the "Begin Run" and press ENTER or the START/PAUSE button.
To exit this screen without starting the pump press either "NAVIGATE TO PREVIOUS" or
"NAVIGATE TO HOME".
While the pump is running the screen displays the actual flow rate.
The pump flow or cycle rate can be adjusted while the pump is running. To adjust,
press ENTER and type the new value, or press the LEFT / RIGHT buttons to decrease /
increase the flow or cycle rate, respectively. Pump speed will vary in steps of 5 cycles
per minute (or the calculated equivalent in the units selected), per keystroke.
Notice that the pump status has changed to "Running".
3.4. Auto Fill Functionality
The controller can receive signals from a container to indicate if it is empty or full.
When a "tank full" signal is received, the pump pauses, and the screen shown is
displayed.
Because the pump is paused, calibration and batch tallies are not lost.
The pump will remain paused until the "full tank" input disappears, and either the
START/PAUSE button is pressed, the "Start Pump" selection is made from the screen
and ENTER pressed, or the "tank empty" input signal is received.
The auto fill functionality is always active, in any of the pump operational modes. To disable this feature, no
signals shall be wired into the controller.
3.5. General Notes on Pump Running
It is possible to navigate to other screens and execute multiple actions while the
pump is running. However, it is not possible to change the program for the running
pump, although other programs can be changed.
It is not possible to start another program, or restart the current program while the
pump is running. The shown error message will be displayed. It is necessary first to
stop the pump.
If the (external) emergency stop is activated, all pumps will stop and the error mes-
sage shown is displayed.
When the emergency stop is cleared, the screen returns to the home screen.