Error messages:
ER>T INLET - inlet sensor failure,
ER> T OUTLET - outlet sensor failure,
ER> T MAX - temperature has exceeded the maximum value,
ER> AIR 1 - air bubbles in the heating box - equipment detection,
ER> AIR 2 - air bubbles in the heating box - program detection.
If the display shows ER> T MAX, ER> AIR 1 or ER> AIR 2 the unit will stop heating.
The unit will not heat again until the failure is resolved and the appropriate value of
water flow is reached.

Temperature adjustment

Turn the knob to the right to increase the temperature value, or to the left to decrease it.
Push the knob to read the temperature value that is stored in memory. Push it again
to read the next stored value. You can switch between the following settings „SINK",
„SHOWER" and „BATH".
To change the temperature setting in memory:
select the temperature setting by pushing the control knob,
push the knob and keep for about 3 seconds until the value starts to flashing,
turn the knob to adjust the value,
push the knob to save the value.
Notice: save the new value within 10 seconds, otherwise you will lose it.
Configuration and parameters view
Set the minimum temperature value then push and keep knob for about 5 seconds
until the display shows „>SET TEMP". Turn a knob to select the required value.
There are some parameters that are not changeable by the user (e.g. >T INLET, >FULL
POW), or can be used to change the work configuration only (e.g. display brightness,
language version). To change the parameters value push (position flickering) and turn
the knob. Push the knob to confirm a changes.
Notice: confirm a new parameter value within 10 seconds, otherwise you will lose it.
The new parameter value will be saved when you exit menu using [>EXIT].
You can switch between the following parameters:
[>SET TEMP] temperature (min-max) - °C,
[>T INLET] inlet temperature value - °C,
[>T OUTLET] outlet temperature value - °C,
[>FLOW] flow rate - l/min,
[>FULL POW] percentage of maximum power with which the unit currently heats, -%,
[>T - h] work time,
[>BRIGH MIN] minimum brightness / stand-by-mode (0 - BRIGH MAX),
[>BRIGH MAX] maximum brightness / active (BRIGH MIN -25),
[>ENGLISH] select language version (POLSKI, FRANCAIS, ENGLISH, DEUTCH,
РУССКИИ),