1.7.4 Encoder Error Detection

For a monitoring of the resolver at channel 1 both input signals SIN+ and COS+ are
monitored. The monitoring for channel 1 will be switched on with parameter Ec.20 Bit 2.
The alarm input triggers an „error"! Encoder 1" (value 32) off, if
• the voltge at the inputs SIN+ or COS+ lies outside the specification.
2.
Installation and Start-up
2.1

Mechanical Installation

All kind of works on the inverter may be carried out by authorized personnel in accordance
with the EMC and safety rules only.
• Switch inverter de-energized and await capacitor discharge time
• Pull off operator
• Remove plastic cover
• Remove fixing bolt
• Fix interface board beginning from the socket connector straightly
• Screw in fixing bolt
• Attach plastic cover
2.2

Electrical Installation

Connection of the encoder cable
Motor encoder plug
1
2
Housing
SIN -
SIN + 10
REF -
REF + 7
COS - 2
COS + 11
12
9
8
external shield at
7
connector housing
10
12
6
11
3
5
4
1
5
Connect-up
the respective
Socket X3A
5
4
3
10
9
8
15
14
13
Housing
14
GND
3
SIN -
8
SIN +
5
REF -
10
REF +
4
COS -
9
COS +
2
1
7
6
12
11
Core color
red
blue
yellow
green
pink
grey

Werbung