Herunterladen Diese Seite drucken

HANSGROHE AXOR Starck 27983-Serie Gebrauchsanleitung, Montageanleitung Seite 4

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
0 4
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ The mesh washer must be insert to protect the shower
against incoming dirt by pipework. Incoming dirt leads
to defects or⁄and can damage parts of the shower;
such caused faults voids all liability and guarantee
claims.
⁄ During installation of the product by qualified trained
personnel, make sure that the entire fastening surface is
even and smooth (no protruding seams or tile offset),
that the finish of the wall is suitable to apply the product
and has no weak points.
⁄ Optimal functioning is only guaranteed with the
combination of Hansgrohe hand showers and
Hansgrohe shower hoses.
SPECIAL INFORMATION FOR THE USA
This unit does not include a wall supply. It must be used
with Hansgrohe model 27458xx3 or another approved
supply that complies with ASME A112.18.1 /
CSA B125.1 including ASME A112.18.3
A S S E M B L Y (see page 33)
T E C H N I C A L D A T A
This mixer series-produced with EcoSmart
Operating pressure:
12231000, 27830XXX, 27980XXX, 27983XXX
Recommended operating pressure:
45722000
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
D I M E N S I O N S (see page 31)
With the excentric washer it is possible to
equalize tolerance of the drilling.
F L O W D I A G R A M (see page 31)
S P A R E P A R T S (see page 35)
XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
340 = Brushed Black Chrome
800 = Stainless Steel Optic
O P E R A T I O N (see page 34)
C L E A N I N G (see page 36)
T E S T C E R T I F I C A T E (see page 38
®
(flow limiter)
max. 0,6 MPa
0,1 - 0,4 MPa
0,25 - 0,4 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C ⁄ 4 min

Werbung

loading