$OZD\V VWRUH WKH DSSOLDQFH RXW RI WKH UHDFK RI FKLOGUHQ LQ D
dry, well ventilated place.

Troubleshooting

Problem
The device does
not function.
Weak suction
power.
Noise during
operation.
The floor nozzle
with turbo brush
is not operating.
Dust escapes
from the dust
container.
The rechargeable
battery does not
keep the charge.
Possible cause
The rechargeable battery
is empty.
The power supply unit is
connected.
The rechargeable battery
is defect.
The battery is nearly
discharged.
The dust container is full. Empty the dust container
The filters are dirty.
A foreign body has been
sucked into the floor
nozzle.
The brush roller is
blocked by dirt.
Incorrect assembly of
suction pipe and / or floor
nozzle.
The dust container is not
closed correctly.
The rechargeable battery
has reached the end of
its life.
Remedy
Charge the battery
Disconnect the appliance
from the power supply unit.
Contact our service or your
dealer.
Charge the battery.
Clean the filters as
described under
³0DLQWHQDQFH´
Remove the foreign body.
If required, disconnect the
floor nozzle from the
suction pipe
Clean the floor nozzle as
GHVFULEHG XQGHU ³&OHDQLQJ´
Check the assembly.
Check the installation of
the filter unit, the cover,
and the base plate.
Contact our service
or your dealer.