Anleitung_BG_GP_1146_NM_SPK1:_
A built-in thermostat protects the motor from
overloading and blocking. The pump is switched
off automatically by the thermostat if overheating
occurs and is switched on again automatically
after cooling.
5.4 Transport (Fig. 2)
The garden pump is equipped with a pull-out
transport handle and wheels to make it easier to
transport.
Pull out the pull-out transport handle as far as it
will go.
The pump can now be pulled along with ease.
After transport, push the pull-out transport handle
back in again.

6. Operation

Install the equipment on a solid and level
surface.
Fill the pump with water at the pressure
connection (Figure 1/Item 2).
Open the discharge line.
Connect the mains cable. The intake process
starts automatically; water can be suctioned in
for up to 5 minutes (maximum suction height).
If the pump is removed again after use, it must
always be refilled with water whenever it is
connected up and used again.
When you have finished drawing water, switch off
the pump at the ON/OFF switch.

7. Replacing the power cable

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, however,
we recommend that you regularly check and care for
the product.
Important!
The equipment must be disconnected from the
power supply (pull the power plug) prior to
performing any maintenance.
15.12.2008
14:34 Uhr
Seite 11
8.1 Servicing
If the equipment becomes clogged, connect the
discharge line to the water line and disconnect
the suction hose. Open the water line. Switch on
the equipment several times for approx.
two seconds. This should resolve the majority of
clog-related problems.
Replacing the mains cable: Important:
Disconnect the equipment from the power
supply! A defective mains cable may only be
replaced by a qualified electrician.
There are no parts inside the equipment which
require additional maintenance.
8.2 Storage
If the pump is not going to be used for a long
time or has to be removed for the winter months,
rinse it out with water, empty it completely and
allow it to dry.
The equipment must be completely drained
before it is subjected to frost.
After long stoppages, make sure the rotor turns
correctly by briefly switching the pump on and
off.
8.3 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info

9. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.