Herunterladen Inhalt Inhalt Diese Seite drucken

High-Pressure Hose And Spray Gun; Connection To The Mains; Cleaning Preserving Agent When Starting-Up Of Operation Initially; Ventilate Unit (Hydraulic System) If The Sound Of The Inlet Valve Is Not Audible - WAGNER Super Finish 21 Betriebsanleitung

Airless hochdruck-spritzgerät
Vorschau ausblenden Andere Handbücher für Super Finish 21:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Starting operation
5
6
7
1
4.3

hiGh-preSSure hoSe and Spray Gun

1.
Screw the high-pressure hose (fig. 10, item 1) onto the hose
connection (2).
2.
Screw the spray gun (3) with selected tip onto the high-
pressure hose.
3.
Tighten the union nut on high-pressure hose so that no
coating material escapes.
3
1
2
32
GB
4.4

cOnnectIOn tO tHe MAInS

Attention
Before connection to the mains, pay attention to the fact that
the mains voltage agrees with the information on the makers'
3
name plate on the rear of the unit.
2
The green control lamp will light up as soon as the mains plug
has been connected.
4
4.5
cleAnInG preServInG AGent wHen
StartinG-up oF operation initially
1. unit with suction system
Submerge suction pipe into a vessel filled with a suitable
cleaning agent.
2. unit with upper hopper
Fill suitable cleaning agent into the upper hopper.
3.
Switch on the unit.
4.
Turn the pressure regulation knob (fig. 11, item 1) to the
right as far as it will go.
5.
Open the relief vale (2),
valve position
6.
Wait until cleaning agent comes out at the return hose.
7.
Close the relief valve, valce position
8.
Pull the trigger guard of the spray gun.
9.
Spray cleaning agent out of the unit into an open collection
container.
2
1
4.6
Ventilate unit (hydraulic SyStem) iF the
SOund Of tHe Inlet vAlve IS nOt AudIBle
1.
Switch on the unit.
2.
Turn pressure regulating knob (fig. 12, item 1)
revolutions to the left.
3.
Open the relief valve (2), valve position
The hydraulic system is ventilated. Leave the unit on for
two to three minutes.
4.
Then turn the pressure regulating knob (1) to the
until stop. Sound of the inlet valve is audible.
5.
If not, repeat points 2 and 3.
The connection must take place through a
correctly earthed two-pole and-earth socket
outlet.
(circulation).
(spraying).
three
(circulation).
right
Super Finish 21 • 23

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Super finish 23

Inhaltsverzeichnis