Setting up the spotlight
• When installing the spotlight above the water surface, allow a safety distance of at least 50 cm from combustible
material.
• Position the unit in such a way that it does not present a hazard to anyone.
• Ensure that the pump is in a secure and stable position.
How to proceed:
 B
• Fasten with wall/floor fixture:
– Mounting plate required.
– Use the wall/floor fixture.
– To establish the screw connection, insert the nut through the small mounting hole and the screw through the
large mounting hole.
 C
• Using a ground stake for installation on the ground:
– Mounting plate required.
– Use the ground stake.
– To establish the screw connection, insert the nut through the small mounting hole and the screw through the
large mounting hole.
 D
• Fastening an OASE fountain pump on the spotlight holder:
– Mounting plate required.
– To establish the screw connection, insert the nut through the small mounting hole and the screw through the
large mounting hole.
 E
• Fastening an OASE fountain pump on the nozzle pipe (e.g. Aquarius Fountain Set):
– Use the nozzle holding fixture.
– To establish the screw connection, insert the nut through the small mounting hole and the screw through the
large mounting hole.
Setting up the transformer
 F
• Install the transformer at least 2 m from the edge of the pond.
Connecting the transformer
How to proceed:
 G
• Insert the connection plug of the spotlight into the socket on the transformer.