Application
Thermostat mixers are designed for hot water supply via
pressurised storage heaters and, utilised in this way, provide
the best temperature accuracy. With sufficient power output
(from 18 kW or 250 kcal/min), electric or gas instantaneous
heaters are also suitable.
Thermostats cannot be used in conjunction with
non-pressurised storage heaters (displacement water
heaters).
All thermostats are adjusted in the factory at a flow pressure
of 3 bar on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see Adjusting).

Specifications

Safety stop
Hot water temperature at supply connection min. 2 °C higher
than mixed water temperature
Thermal desinfection possible
Minimum flow rate
If static pressure exceeds 5 bar, a pressure reducing valve
must be fitted.
Installation
The projection can be increased by 20mm with an extension,
see Replacement Parts, page 28, Prod. no. 07 130.
Reversed connection (hot on right - cold on left).
Replace thermostatic compact cartridge, see Replacement
parts, page 28, Prod. no.: 47 175 (1/2").

Operation

The safety stop limits the temperature range to 38 °C.
The 38 °C limit can be overridden by pressing the button, see
page 3 Fig. [1].
Adjusting the economy stop, see Fig. [2].
If a higher flow rate is desired, the stop can be overridden by
pressing the button, see Fig. [3].
Shut-off handle and diverter operation,
see Fig. [3] .
Adjusting
Temperature adjustment, see page 3 Figs. [1]
and [2].
Temperature end stop
If the temperature end stop is at 43 °C, insert accompanying
temperature limiter in temperature selection handle,
see Fig. [3].
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.

Maintenance

Inspect and clean all parts, replace if necessary and lubricate
with special valve grease.
Shut off the hot and cold water supply.
Thermostatic compact cartridge, see page 27.
Readjustment is necessary after every maintenance
operation on the thermostatic compact cartridge (see
Adjusting).
Shower, see page 27.
The function of the SpeedClean nozzles is
guaranteed for a period of five years.
Thanks to the SpeedClean nozzles, which must be regularly
38 °C
cleaned, limescale deposits on the rose can be removed by
simply rubbing with the fingers.
Replacement parts
= 5 l/min
See page 28 ( * = special accessories).
Care
For directions on care, refer to the accompanying Care
Instructions.
Consignes de sécurité
Prévention d'échaudage
Pour des points de puisage où la température de
l'eau est particulièrement critique (hôpitaux, écoles,
résidences médicalisées), il est recommandé de
systématiquement utiliser des thermostats pouvant être limités
à 43 °C. Une butée de température permettant la limitation est
incluse avec ce produit. Pour les systèmes de douche dans les
écoles maternelles et dans certaines parties de résidences
médicalisées, il est généralement recommandé de ne pas
dépasser une température de 38 °C. Utilisez ici des
thermostats Grohtherm Special avec poignée spéciale pour
l'aide à la désinfection thermique et la butée finale de sécurité
correspondante. Respectez les normes en vigueur
(par ex. EN 806 2) ainsi que les règlementations techniques
pour l'eau potable.
Domaine d'application
Les robinetteries thermostatiques sont conçues pour fournir de
l'eau chaude avec des accumulateurs sous pression et
permettent d'obtenir une température de l'eau extrêmement
précise. Si la puissance est suffisante (à partir de 18 kW,
ou 250 kcal/min), des chauffe-eau instantanés électriques ou
au gaz conviennent également.
Les thermostats ne peuvent pas être utilisés avec des
accumulateurs sans pression (chauffe-eau à écoulement
libre). Tous les thermostats sont réglés en usine sur une
pression dynamique de 3 bars. Si des différences de
température devaient apparaître, régler le thermostat en
fonction des conditions locales d'utilisation (voir Réglage).
6
2

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis