At the suspended part, always install a safety-rope that can hold at least 12 times the weight of the
installation. You must only use safety-ropes with quick link with screw cap. Pull the safety-rope through the
attachment eyelet and over the trussing system or a safe fixation spot. Insert the end in the quick link and
tighten the safety screw.
The trussing system must always be earthed!
Before taking into operation for the first time, the installation has to be approved by an expert!

5.3 Connections

5.3.1 Connection with the mains

Connect the device to the mains with the industrial plug.
The occupation of the connection-cables is as follows:

5.3.2 Outputs

Output is via 6 safety connectors.
Connect your loads via the output-sockets. The maximum load per channel is 3,680 W (resistive). Please
note that the maximum current must never be exceeded.

6. OPERATION

The AB-616-R Alubar is a holding device. Please control the individual spotlights via your controller.

7. CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.