Installation instructions Boreal

General instructions

Preparation
Installation
Repairs
Technical details Boreal
General instructions
The Boreal is available in various models and there is
even a rotatable version. The rotatable hearth can turn
120º at most while meeting all fire safety standards. The
stove can be rotated gradually (15°). To turn the rotatable
model properly, the external air supply and the flue tube
must be at right angles. The Boreal stove is provided with
an energy-saving valve in the pipe socket for having a
higher output during operation. The Boreal also has the
option for connecting an external air supply (only via
the bottom side).
The diameter of the air supply duct is important; the
diameter of the air supply duct is 100 mm.
The heating device must be placed by an acknowledged
installer and according to the installation instructions
given below. The national and local rules and regulations
for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee
if the stove is connected or installed incompletely or
incorrectly.
It is not allowed to place the stove in:
• Arcades and corridors accessible to the public.
• Stairwells, except in buildings with no more than 2
dwellings.
• Spaces where highly flammable or explosive materials
are used.
• Spaces where an exhaust system is used or where a
mechanical exhaust system is placed, except when
the air supply is taken directly from outside to assure
a hazardless combustion.
Preparation
The chimney flue
Before placing the stove you must observe the following
points:
• If the stove is connected to an existing chimney, you
must first have the chimney professionally cleaned
22
22
22
23
24
25
and checked by a qualified chimney sweep company.
Any cut-off valves or stop valves must be removed.
• The flue tube of the stove must be connected with the
chimney without diversions.
• The underpressure in the flue duct must be at least
10 Pa or 0.1 mbar. If this value is not reached you
must lengthen the tube or place a flue gas ventilator
to reach these values.
• The chimney must always reach outlet area 1. If it does
not, it will increase the chance of a reverse chimney
flow or inverted draught.
• At the time of placing the stove, the chimney flue