Technical details Boreal
Technical details
Door latch
Nominal capacity*
Diameter tube for combustion gases
Maximum lumber supply in the stove
Maximum brown coal supply
Volume of the combustion chamber
Surface bottom of combustion chamber
* a nominal heat of 7 kW is obtained with a chimney draught of 0,10 mbar
Fuel, wood logs, 30 x 10 cm
Maximum supply
Primary air valve
Secondary air outlet
Fuel burning period
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
When door is closed
Flue gas quantity
Flue gas temperature
Pre-pressure
Yield
CO at 13% O2
Particulate matter
Certificate Institute 1625. Test standard EN 13240. Test report no. RRF-40 09 1849
Ba
I/II
7
kW
150
mm
3
kg
-
kg
0,05
m3
0,09
m2
3 pieces
max.
max.
about 1 hour
logs
6,6
g/s
340
˚C
0,13
mbar
78,4
%
0,05
%
23
mg/m3
25