Herunterladen Inhalt Inhalt Diese Seite drucken

Preparing The Electrical Installation; Installation; Siting; Removing The Casing Parts - STIEBEL ELTRON WPE-I 33 H 400 Premium Bedienung Und Installation

Vorschau ausblenden Andere Handbücher für WPE-I 33 H 400 Premium:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION

Installation
9.5

Preparing the electrical installation

WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with national and regional regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3 mm contact separation.
This requirement can be met by using contactors, circuit
breakers, fuses/MCBs, etc.
Note
The specified voltage must match the mains voltage. Ob-
serve the type plate.
f Use cables with the relevant cross-sections. Observe the ap-
f
plicable national and regional regulations.
Electrical data is provided in chapter "Specification / Data table".
Note
The appliance includes an inverter for the variable speed
compressor. In the event of an error, inverters can cause
DC residual currents. If RCDs are provided, they must be
type B AC/DC-sensitive.
A DC residual current can block type A RCDs.
f Ensure that the appliance power supply is discon-
f
nected from the distribution board.
10. Installation
10.1 Transport
f Transport the appliance in its packaging in an upright posi-
f
tion to protect it against damage.
f Protect the appliance against heavy impact during transport.
f
- If the appliance needs to be tilted during transport, this must
only be for a short time and it must only be tilted on one of
its longitudinal sides.
The longer the appliance is tilted, the greater the distribution
of refrigerant oil inside the system.
- Storage and transport at temperatures below - 20 °C and
above + 50 °C are not permissible.

10.2 Siting

f Remove the packaging material.
f
f Lift the appliance off the pallet with a forklift truck.
f
f Position the appliance on the prepared substrate.
f
f Maintain the minimum clearances.
f
f Level the appliance horizontally by adjusting the feet.
f
www.stiebel-eltron.com

10.3 Removing the casing parts

WPE-I 33 H 400 Premium  | WPE-I 44 H 400 Premium
1.
f Undo the closure on the top cover.
f
f Pull the top of the front panel forwards.
f
f Remove the front panel by lifting it upwards.
f
WPE-I 59 H 400 Premium  | WPE-I 87 H 400 Premium
1.
f Undo the two closures on the top cover.
f
f Pull the top of the front panel forwards.
f
f Remove the front panel by lifting it upwards.
f
2.
3.
2.
3.
WPE-I H 400 Premium |
53

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wpe-i 87 h 400 premiumWpe-i 59 h 400 premium

Inhaltsverzeichnis