Herunterladen Inhalt Inhalt Diese Seite drucken

Daikin R410A-Series Installationsanleitung Seite 16

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
Indoor Unit Installation
3) Pass the drain hose and refrigerant pipes through the wall hole, then
set the indoor unit on the mounting plate hooks by using the
markings at the top of the indoor unit as a guide.
4) Open the front panel, then open the service lid.
(Refer to preparation before installation.)
5) Pass the inter-unit wire from the outdoor unit through the
feed-through wall hole and then through the back of the
indoor unit. Pull them through the front side. Bend the ends of
tie wires upward for easier work in advance. (If the inter-unit
wire ends are to be stripped first, bundle wire ends with
adhesive tape.)
6) Press the bottom frame of the indoor unit with both hands to
set it on the mounting plate hooks. Make sure the wires do
not catch on the edge of the indoor unit.
3-2. Left-side, left-back, or left-bottom piping
How to replace the drain plug and drain hose
• Replacing onto the left side
1) Remove the insulation fixing screw on the
right and remove the drain hose.
2) Remove the drain plug on the left side and
attach it to the right side.
3) Insert the drain hose and tighten with
included insulation fixing screw.
* (Forgetting to tighten this may cause
water leakages.)
1) Attach the drain hose to the underside of the refrigerant pipes
with adhesive vinyl tape.
2) Be sure to connect the drain hose to the drain port in place of
a drain plug.
9
Hang indoor unit's hook here.
When stripping off
the ends of inter-unit wire in
advance, cover the ends with
insulating tape to make it
easier to pass the wire.
Drain hose attachment position
* The drain hose is on the back of the unit.
Left side
Front side of unit
Attachment on the left side
Insulation
fixing screw
Drain hose
Remove pipe port cover here for left-bottom piping.
How to set drain plug
Mounting plate
Mounting plate
Inter-unit wire
Wire guide
Right side
Attachment on the right side (factory default)
Insulation
fixing screw
Drain hose
Remove pipe
port cover
here for left-
side piping.
Left-bottom piping
Do not apply lubricating
oil (refrigerant oil) to the
drain plug when inserting it.
The application of lubrication
oil to the drain plug will deteriorate
the plug and cause drain leakage
from the plug.
Insert a hexagonal wrench (4mm).
English
Left-side
piping
Left-back
piping

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis