9. Trouble Shooting
Problem
Cause
Motor doesn't start
No electricity
Piezo doesn't ignite
Electrode incorrectly adjusted
No gas at burner
- Gas valve is closed
- Gas cylinder is empty
- Gas hose or connection leaks
Burner ignites, flame is
- The thermoelement was not
extinguished as soon as the gas
-
warm enough
valve is released
- The safety thermostat
-
-
switches off
Burner goes out while in use
- Gas flow too high
- Air input too low
Important!
Have repairs carried out only by specialist workshops or ISC.
21.08.2006
10:28 Uhr
Seite 13
Remedy
- Check electrical outlet
- Check mains cable
Check electrode and precisely
set according to diagram
- Open valve
- New gas cylinder
- Locate point of leak with soap
-
foam and repair
- Repeat ignition procedure
-
while pressing in the gas
-
valve knob
- Allow the heater to cool for a
-
few minutes and reignite
- Have the pressure regulator
-
inspected and replace if
-
necessary
- Check the suction grid and
-
clean
- Inspect ventilator