Error / cause / repairing
The pump is very loud and does not bring the normal power.
Wrong motor direction of rotation
The pump is loud and does not take full power.
The engine cover swipes.
The pump is not running or is running difficultly and slowly.
A phase is missing.
When turning on, the fuses switch.
incorrect fuses
The motor protection is triggered.
incorrect setting
The pump can not be switched from the pool.
The switching tube is kinked or jammed.
/ The hose is too long.
Fuses/ power supply/ motor protective
button
10
Reverse the polarity of motor by swapping the phase
(400 V).
Only by licensed electrician!
Fan cover loosely, fix properly.
Change supply line.
Use fuse 16A inert.
Set the correct current value + 10%.
Check whether the pump can be switched from the
control box.
Shorten the hose, if necessary.
Check the fuses and the power supply. Test the motor
protective button.