Herunterladen Inhalt Inhalt Diese Seite drucken

Safety And Troubleshooting; Troubleshooting Table - Portotecnica Genius 1300 DP Gebrauchs- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
The machine features some safety functions that have been described in the chapters concerning the use of both versions (with or
without an engine): for instance, the system for stopping all functions to prevent the battery from running out or the possibility of
turning the red key to disable the self-braking function in the event that the machine has to be pushed.
TRACTION
ENABLED
Safety
Machine behaviour
code
All machine functions and the
C 101
traction system are blocked
C 102
The machine does not start or
stops if it was running
C 104
All machine functions stop
C 106
The machine does not start

SAFETY AND TROUBLESHOOTING

TRACTION
DISABLED
SEE SAFETY CODE C 999

TROUBLESHOOTING TABLE

English
Fault
The temperature of the traction
motor has risen above 95°C or the
alternator temperature has risen
above 150 °C.
They may be a problem affecting
the traction system or the fuse
The temperature of the electronic
control circuits is very high
(105°C).
Interruption of a cable in the
potentiometer of the accelerator
pedal.
- 27 -
Remedy
If you have driven the machine up
a slope, let it cool down for 20
minutes-
- Make sure the cooling fan is
running
- Make sure the brake is
disengaged
- Make sure the traction wheels run
freely
Turn the machine off, wait 5" and
try again. If the C102 situation
persists, call the service centre.
If the ambient temperature is high,
stop the machine and wait 20
minutes before restarting. If the
situation persists, call the service
centre.
Check the connections of the
accelerator pedal potentiometer or
the status of the latter.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Genius 1400 dp

Inhaltsverzeichnis