Herunterladen Inhalt Inhalt Diese Seite drucken

Fire Safety - Kirami MACU Bedienungsanleitung

Hot tub heater
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
21/60
© Kirami Oy, Finland
Installation for Original Easy and Comfort Cozy
tubs
Heater for plastic tubs is connected with rubber hoses to the
Ø75mm PVC pipes on the tub. In this installation the heater is
placed on the same level with the tub so both are directly in
contact with ground. And the heater is not hanging in the air.
On some plastic tubs this means that you have to add some
support under the heater e.g. concrete slabs or bricks. In the
left picture plastic tub connection pipes. On the right side you
see an example of MACU connected with plastic tub.
Installation further away from the tub
The standard heater should not be installed further away from the tub. If you are planning
installation further away from the tub you should purchase an extension tube set with intermediate pipes,
extra clamps and rubber hoses. When installing further away the heater must be a bit lower than the
tub so that the natural circulation of heated water works
Note that a heater that is installed lower will not empty properly which may cause a risk of freezing
in winter. In case the heater installed further away, the heater must have supports underneath.

FIRE SAFETY

If the heater is located near buildings, for example on the
side of a terrace, the distance of the chimney from any
combustible materials must be adequate. Remember to
check the distance both laterally and vertically so that
there isn't any risk of fire. Safe minimum distance, from
the chimney's upper end, laterally is three (3) meters.
Shorter distance laterally is adequate in other parts of the
chimney. If the chimney is closer to any combustible
materials you must use special insulated chimney, which
has to be purchased separately.
When positioned close to the roof or when taken through
it, the top end of the insulated chimney must be at least
one (1) meter above the surface of the roof. Ask your local fire officer for more information.
Notice also the fire safety in front of the furnace. There shouldn't be any combustible materials in
front of the furnace. There should be an area, which is demonstrated in the picture that should be
made of incombustible material such as concrete, sand or metal.
Grates
A fire grate is installed to the heater, with one grill plate.
An air guide is installed to the top shelf which guides the fire air
circulation on the top part of the hearth. The heater must not be used
without these parts.