Regeneration time
Note:
Determine the time of regeneration.
A
Press MODE until display position point to the Time of Regeneration icon.
B
Press and hold
C
Set the time with
D
Press MODE to go to the next parameter, or press
return to the service mode.
Water Hardness or number of days between regenerations
Note:
Determine the water hardness in mgl.(metered) or the number of days between regenerations (time clock).
A
Press MODE until display position point to the Hardness or Days between
regenerations icon.
B
Press and hold
C
Set the water hardness or the number of days between regenerations with
.
D
Press MODE to go to the next parameter, or press
return to the service mode.
4.2.
Diagnostic mode
To access the recorded informations, press MODE and
MODE twice to see the next diagnostic. Press
5 .

Operation

5.1.
Recommendations
• Use only regenerate salts designed for water softening EN973;
• for optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• do not use ice melt, block, or rock salts;
• the sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the lifetime
of the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the
system.
5.2.
Manual immediate regeneration
A
Press and hold
for 5 seconds.
6 .

Error codes

The following error codes may be displayed during operation:
---0
Cam sense error:
---1
Cycle sense error:
--- 2
Regen failure:
---4
Fail safe error:
7 .

Maintenance

Mandatory:
Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance record book.
Mandatory:
The maintenance must be done by a professional certified by Pentair, otherwise the warranty will void.
8 .

Troubleshooting

Please follow this procedure for any technical support:
A
Collect the required information for a technical assistance request.
Product identification (see 2.1. Serial label location, page 5 and Original settings, page 2).
B
Contact your local dealer who installed this device (see contact details on last page).
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
Ref. MKT-UG-005 / B - 16.01.2018
or
until the Programming icon appears.
or
.
or
until the Programming icon appears.
to exit the diagnostic mode.
Unplug the unit and plug it back. If error continue, call technical support.
Unplug the unit and plug it back. If error continue, call technical support.
Perform a manual regeneration. If error continue, call technical support.
Unplug the unit and plug it back. If error continue, call technical support.