Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Cleaning The Inspection Window; Fuses; Trouble-Shooting List - Truma S 5004 Gebrauchsanweisung Und Einbauanweisung

Vorschau ausblenden Andere Handbücher für S 5004:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Maintenance

Cleaning the inspection window

Clean the inspection window with water (no cleaning
agents). Use a soft sponge, woollen cloth or chamois
leather. Never use sharp objects or solvent to remove stains.

Fuses

Depending on the model, a fuse (2 A) is installed in the sup-
plied power cable. Only replace faulty fuses with ones of the
same type.

Trouble-shooting list

Fault
– No flame or embers.
– No noise.
– The flame effect does not
respond to the switching
commands of the remote
control.
– Function display of the
remote control does not
acknowledge the push of
a button.
– Flame effect does not
function.
If this does not solve the problem, please contact the
Truma Service.

Disposal

The device must be disposed of in line with the administrative
regulations of the respective country in which it is used. Na-
tional regulations and laws (in Germany, for example, the End-
of-life Vehicle Regulation) must be observed.
In other countries, the relevant regulations must be observed.
8
Cause / Action
– Increase the brightness.
– Increase the volume.
– Point the remote control
toward the IR receiver
when sending switching
commands.
– Check the function of the
batteries in the remote
control.
– Check the power cable
and that the plug is insert-
ed firmly.
– Check the fuse in the on-
board power supply / pow-
er cable.
– Check whether the supply
battery functions flawless-
ly and if it is fully charged.
– Reset the system.
To do this, interrupt the
power supply for at least
20 seconds.

Technical data

Power supply SELV (Safety Extra Low Voltage)
12 V DC
Current consumption
0.2 – 0.8 A
Quiescent current
< 1 mA
Weight
approx. 2.8 kg
The right to effect technical modifications is reserved!

Declaration of conformity

The device has been tested by the DVGW and is entitled to
bear the CE symbol. (Declaration of conformity – see operating
instructions for the respective heater).