Setup

8
Setup
8.1

Single-device system

12
Siemens Building Technologies
Fire Safety & Security Products
1-4 cameras
Fig. 2
Single-device system
Fig. 3
SISTORE CX4 connections
1.
Place the device on a desk or table or install it in a rack. See Section: 7.1
Tabletop operation and Section: 7.2 Rack installation.
2.
Connect the cameras (max. 4) to the video inputs (
If loop-through is necessary, set the terminating resistor (
the video cable extension to the video loop (
3.
Connect an analog monitor to the device (
4.
Connect the client PC to the network switch, and use the network cable
provided to connect the switch to the device (
5.
Connect the power supply unit to the SISTORE CX4 (
power source.
6.
Switch on the analog monitor.
After a short wait, the IP address of the SISTORE CX4 will appear on the
screen.
7.
Connect the client PC to the power supply.
8.
Start the client PC.
9.
Set the IP address of the client PC. See Section: 8.4 Setting the IP address of
the client PC.
Network Switch
SISTORE CX4
).
4
Client-PC
Analog Monitor
).