Exhaust duct system

The exhaust gas duct system must be made in
such a manner as to achieve a complete extrac-
tion of combustion products to the outside of
living space. The flue gas is vented directly
through the upper grille. Do not use any kind of
aluminium flue pipe to lead the flue gas out.
The T-piece (Fig. 17) must be aligned with the
exterior wall.
CAUTION!
An installation other than described will
reduce the cooling capacity and jeopardise
the manufacturer's warranty/product liabi-
lity.
45°
Fig. 17
4.5

Installation recess

The refrigerator must be installed draught-proof
in a recess (also refer to Section "4.1.3"). The
measurements of the recess are stated in the
table below. Push the appliance far enough into
the recess until the front edge of the refrigerator
casing is aligned with the front of the recess.
Allow a gap of 15-20 mm between the back wall
of the recess and the refrigeration unit. The floor
of the recess must be level, allowing the appli-
ance to be pushed easily into its correct positi-
on. The floor must be substantial enough to
bear the weight of the appliance. Ensure that
the refrigerator is installed level in the
recess.

4.5.1 Recess dimensions

Height H
1297 mm
13
Installation
Width B
DepthT
423 mm
552 mm