Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

GENERAL WARNINGS

Do NOT use this gas heater if any part has
been under water. Immediately call a qualified
service technician to inspect the heater and to
replace any part or control system and any gas
control which has been under water.
Do NOT use in windy conditions.
Keep all electrical cords away.
Do not touch hot surfaces until the unit has
cooled unless you are wearing protective gear
such as insulated pot holders or heat resistant
gloves or mittens to avoid burns.
Children and adults should be alerted to the
hazards of high surface temperatures and
should stay away to avoid burns or clothing
ignition.
Do NOT hang or place clothing or other flammable
materials on or near the gas heater.
Any guard or other protective device removed
for servicing the heater must be re-placed prior
to operation.
Do NOT attempt to move or store this outdoor
heater until all parts are cool.
Use only the regulator and hose assembly provided.
Use only replacement regulator and hose assemblies
specified by the manufacturer.
Do not attempt to disconnect the gas regulator
from the tank or any gas fitting while the outdoor
heater is in use.
Always shut off gas supply at the tank valve
when the heater is not in use.
It is essential to keep the outdoor heater
valve compartment, burners, and circulating
air passages clean. Inspect outdoor heater
for debris before each use.
Prior to each gas heater operation, check the
hose for evidence of excessive abrasion or
wear. If the hose is damaged, cut or cracked, it
must be replaced before using the gas heater.
The hose assembly can only be replaced by a
hose assembly specified by the manufacturer.
WARNING: When the national conditions require
it, it's necessary to change the flexible tube.
ENGLISH
GAS (LPG) WARNINGS
LP gas is flammable and hazardous if handled
improperly. Please review the characteristics
before using any LP gas product.
Propane Characteristics: Flammable, explosive
under pressure, heavier than air, and settles in pools
in low areas. In its natural state, propane has no
odor. For your safety, an odorant is typically added.
Contact with propane could burn the skin.
Propane is extremely flammable and hazardous
if handled improperly.
Cylinders must be stored outdoors in a
well-ventilated area out of reach of children.
Disconnected cylinders must have threaded
valve plugs tightly installed and must not be in
a building, garage or any other enclosed area.
Never use a propane cylinder with a damaged
body, valve, collar or footing.
Dented or rusted propane cylinders may be
hazardous and should be checked by your
propane gas supplier.
LP gas tank must be arranged for vapour withdrawal.
The LP gas tank must have a tank collar to
protect the tank valve.
The LP gas tank should not be dropped or
handled roughly.
Never store your LP gas tank where temperatures
can reach over 52°C(125°F).
Do not store the LP gas cylinder in direct sunlight
or near a source of heat or combustion.
Never keep a filled LP gas tank in a hot car or
car trunk. Heat will cause the gas pressure to
increase, which may open the relief valve and
allow gas to escape.
Place dust cap on valve outlet whenever the LP
gas tank is not in use. Only install the type of
dust cap on the LP gas tank valve outlet that is
provided with the LP gas tank valve. Other types
of caps or plugs may result in leakage of propane.
Do not store a spare LP gas cylinder under or
near this appliance.
Never fill the LP gas cylinder beyond 80% full.
LP gas cylinders should be filled only by a
certified LP gas dealer.
7
The pressure regulator is set for 30-50mbar.
Regulator outlet pressure is 30~50mbar de-
pend on country of use.
Never attempt to attach this appliance to the
self-contained LP gas system of a camper
trailer, motor home or house.
Always use the pressure regulator and
hose assembly provided with the appli-
ance to connect to a LP gas cylinder.
Never connect to an unregulated LP gas
supply.
Contact your retailer's customer service depart-
ment for replacement parts.
Hand turn the manual gas control valve. Never use
tools. If the valve will not turn by hand, do not try to
repair it. Call a certified gas technician. The use of
force or any self-attempted repair may result in a
fire or explosion.
Use only the type of gas and the type of LPG
cylinder specified by the manufacturer.
Appliance is fitted with gas regulator, flexible
gas rubber pipe and clamps according to the
National Rules in force of the country of desti-
nation.
Appliance must use an approved gas regulator
(approved for a working temperature not lower
than 50 ˚C) according to the EN Standard (see
minimum, nominal and maximum pressure - gas
regulator inlet and outlet connection according
to the National Rules in force) and flexible gas
hose according to EN Standard (with proper inner
diameter according to gas inlet connection and
National Rules in force) with a length not over
m and approved for a working temperature not
lower than 60 ˚C.
When substitution will be necessary, you have
to purchase suitable gas regulator, flexible
gas rubber pipe and clamps from your local
gas dealer; gas regulator should be substi-
tuted not over 10 years old.
Flexible gas rubber pipe must be carefully,
avoiding any twisting. Never use a damaged gas
regulator.
Always perform a leakage test on gas connec-
tions whenever a LPG cylinder is connected. If
bubbles form in the leakage test solution, do not
use it. Never use a flame to test for leakages. It is
strictly forbidden and dangerous!
1.7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis