Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Technical Characteristics - Nice TCE Anweisungen Und Hinweise Für Den Installateur

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
4) Diagnostics and Signals
TCE has two signalling LEDs which indicate the state of the relays.
Normally, they are "ON". If they are off, this indicates a state of alarm,
meaning that the sensitive device has either triggered or malfunc-
tioned.
State
Signalling
Led1: on
OUT1: On
Led1: off
OUT1: Off
Led2: on
OUT1: On
Led2: off
OUT1: Off

5) Maintenance

To maintain the guaranteed level of safety of the TCE, regular main-
tenance must be performed at max. 6 month intervals.
!
The maintenance operations must be performed in strict
compliance with the safety directions provided in this manual
and according to the applicable legislation and standards.
6) Disposal
This product is made up of different materials, some of which can be
recycled, such as plastic container, others must be disposed of as
waste, such as electronic board.
1. Disassemble TCE following in reverse order the procedures
described in chapter "Installation".
2. As far as possible, separate all parts that can or must be recycled
or disposed of according to special procedures.

6) Technical characteristics

Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In any
case, the manufacturer guarantees their functionality and fitness for the intended purposes.
Note: All the technical characteristics refer to a room temperature of 20°C (±5°C)
Technical Features of the TCE detection unit
Type:
Adopted technology
Supply voltage
Absorbed current with 24 Vac:
Absorbed current with 24 Vdc:
Phototest input voltage:
Range of the sensitive device input (Rs):
Limits of the activated state (On):
Limits of the deactivated state (Off):
Sensitive device cable length:
Out1 Response Time:
Out2 Response Time:
OUT1 and OUT2 output relay contacts:
OUT1 and OUT2 output relay contacts duration:
Operating temperature:
Use in acid, saline or potentially explosive
atmosphere:
Protection class:
Dimensions and weight:
Description
Output N°1 Activated
Output N°1 Deactivated
Output N°2 Activated
Output N°2 Deactivated
Detection unit utilised to produce electro-sensitive protection equipment (ESPE), complete with
8.2KΩ constant resistance sensor devices used for the automation of doors and gates.
2 independent channels with window comparators and relay output
15÷28Vac (±15%) 50/60Hz; with insulation transformer which conforms with EN 61558
12÷30Vdc (±15%)
< 200mA rms
< 50mA
Same limits as "Input Voltage"
Typical 8.2KΩ ± 25% for the activated state (On)
with Rs > 4,725Ω and Rs < 10,925Ω
with Rs <1,520Ω or Rs > 18,900Ω
Max. 30m
<5ms (typical 3.3ms)
1,6s ± 25%
Max. 0.5A and max. 48Vac (resistive load: cosϕ=1)
Mechanical lifespan > 1,000,000 cycles; Electrical lifespan > 200,000 cycles (at 0.25A 24Vcc)
-20 ÷ 55 °C
No
IP 20
60x59x422 with flaps 60x38x422 without flaps/approx. 55g
1
2
Led 1
NC
NO
8
1
2
3
1. Check all TCE parts for wear with special attention to dirt, ero-
sion, rust, overheating.
2. Perform all tests and checks as envisaged in the section "Test-
ing".
3. Sort the various materials and consign them to local licensed
firms for recovery and disposal.
!
Some electronic components may contain polluting sub-
stances; do not pollute the environment.
3
4
5
Led 2
IP10
12 / 24 Vac/dc
Out 0,5A 48Vac/dc
NC
TACTO
4
5
GB
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis