warning: when the pump stops, the pipes are under pressure consequently we recom-
mend opening a tap to discharge the system before carrying out any work.
l The electrical connections are always to be carried out by an authorised professional.
l The Fluomac® may be used by children aged 8 years and above as well as persons with red-
uced physical, sensory or mental abilities or those who lack skills, experience and knowledge
only if they are supervised. These aforementioned persons should only use the appliance
while adhering to safe instructions and resulting dangers.
l Cleaning and maintenance must not be carried out by children without supervision.
l The pump must not be used or operated under any circumstances when there are people in
the same water.
l Under certain cirumstances, it is possible that that contamination of water is caused by leakage.
THE mANUFACTURER EXPLAINS:
l To take over no responsibility in the case of accidents or damages on the basis of careless-
ness or disregard to the instructions in this book.
l To reject every responsibility for the damages which originate from the improper use of the
device.

13. RECOGNISING AND REPAIRING OF mISTAkES

Problem
Possible cause
1. The Fluomac® was mounted
the other way round
The pump does not deli-
2. The priming process was not
ver any water
implemented correctly
3. The suction hose is not proper-
ly immersed in the liquid
1. There are leaks in the system
The pump does not re-
2. The hose or suction filters are
ach the desired pressure
clogged
3. The foot valve is blocked
1. The pressure is set too high
The device stops the
2. The pump's thermal protection
pump from running even
may prevent the pump from
in presence of water
running
The pump does not start
The pressure is set too low
when a tap is opened
1. There are leaks in the system
The pump starts and
2. The flow of water from the tap
stops frequently
is too low
1. The flow switch of the Fluo-
mac® is dirty
2. There are significant leaks wi-
The pump keeps running
thin the system
and does not stop
3. A check valve has been instal-
led before or after the Fluo-
mac® device
Solution
1. Check the installation of the
device and correct if necessary
2. Press and hold the RESET but-
ton until the flow is regular
3. Check that the suction hose is
well immersed in water
The device stops the pump from
running even in presence of water
1. Decrease the pressure until the
problem is resolved.
Contact a professional installer.
2. Check the pump
Increase the pressure until the
problem is resolved.
Contact a professional installer
1. Check for any leaks and resol-
ve as necessary
2. Contact technical support
1. Check the device
2. Check the plumbing system
3. Remove any valves from the
system

14. NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are
caused by our units if no changes were made to the equipment. If repairs are carried out by our
authorized service, we are only liable if original spare parts and accessories were used.

15. NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are
not permitted to be disposed in your household garbage. We are registered at the
German registration department EAR under the wEEE-No. DE25523173.
This symbol means, that you're not allowed to treat this product as a regular
household waste item – it has to be disposed at a recycling collection point of electri-
cal devices. This is the best way to save and protect our earth.
THANk YOU FOR YOUR SUPPORT!

16. EU DECLARATION OF CONFORmITY

The products listed overleaf accordance with the marketed in accordance with the relevant
provisions listed below, the relevant EU directives and harmonized with EU standards for safety.
This declaration is valid insofar on the product, no changes are made.
Authorized person to keep the technical documents:
1A-Profi-Handels GmbH · Unterriethstraße 37 · D-65187 Wiesbaden
Low Voltage Directive (2014/35/EC)
EC Electromagnetic compatibility directive (2014/30/EC)
The following harmonized standards:
EN 60730-1:2011; EN 60730-2-6:2008
EN 61000-6-1:2007; EN 61000-6-3:2007+A1:2011
EN 50581:2012
Wiesbaden, 1st March 2017
Peter Neumüller
ppa. Peter Neumüller
English 7