Herunterladen Inhalt Inhalt Diese Seite drucken

Waeco CA-45 Bedienungsanleitung Seite 28

Vorschau ausblenden Andere Handbücher für CA-45:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
_CA-45.book Seite 28 Montag, 3. Mai 2004 9:22 09
Troubleshooting
10
Troubleshooting
In the event of malfunction, please check the following:
Fault
The cooler does not
work.
The cooler does not
start up after a long
period of inactivity.
28
Possible cause
Suggested remedy
The cooler is not
Check if the voltage supply is in full
properly connected to
working order.
the electricity supply.
Check if all electrical contacts are in full
working order.
Check if the voltage supply corresponds to
the value on the type plate.
Check if the thermostat control is
switched on.
Check if several energy sources are
connected at the same time.
The cooler is not
Check if the gas supply is in full
properly connected
working order.
to the gas.
Check if the valve on the gas bottle is open.
Check if there is still gas in the bottle.
Check if several energy sources are
connected at the same time.
Hold the gas control down longer
when igniting.
The cooler has not
Check if the device is horizontal.
been set up properly.
Check if the ventilation of the device
is sufficient.
The cooler has not
Check if warm food has been put into
been filled properly.
the device.
Check if the cooling space has been
overfilled or packed too densely.
The refrigerant circuit
This can only be repaired by an authorised
is defective.
customer services unit.
Disconnect the device from the energy
supply and turn the cooler upside down
and wait around five minutes.
Turn the cooler the right way up again
and switch it on again.
CA-45, CAB-45

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cab-45

Inhaltsverzeichnis