Danfoss RET2000 MD Installationsanleitung Seite 11

Electronic digital thermostat with lcd, delayed start
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
S1 – Lower Temperature Limit
This setting allows for a Lower Temperature Limit to be set.
The Lower Limit can be set between 5°C (41°F) and 30°C
(86°F).
Default – 5°C/41°F
S2 – Upper Temperature Limit
This setting allows for a Upper Temperature Limit to be set.
The Upper Limit can be set between 5°C (41°F) and
30°C (86°F). However, this will be limited by the Lower
Temperature Limit set in S1 therefore the Upper Temperature
Limit cannot be less than the Lower Temperature Limit.
Default – 30°C/86°F
S3 – Set Point Power-Up Temperature
This setting defi nes the set point at power up when Button
Lock is enabled on the DIL switch.
This can be set between the Lower and Upper Temperature
Limits set in S1 and S2.
Default – 21°C/70°F