S1 – Lower Temperature Limit
This setting allows for a Lower Temperature Limit to be set.
The Lower Limit can be set between 5°C (41°F) and 30°C
(86°F).
Default – 5°C/41°F
S2 – Upper Temperature Limit
This setting allows for a Upper Temperature Limit to be set.
The Upper Limit can be set between 5°C (41°F) and
30°C (86°F). However, this will be limited by the Lower
Temperature Limit set in S1 therefore the Upper Temperature
Limit cannot be less than the Lower Temperature Limit.
Default – 30°C/86°F
S3 – Set Point Power-Up Temperature
This setting defi nes the set point at power up when Button
Lock is enabled on the DIL switch.
This can be set between the Lower and Upper Temperature
Limits set in S1 and S2.
Default – 21°C/70°F
Danfoss Heating
GB
GB
DE
DK
ES
FR
NL
RU
TR
11