Locking and Limiting
The RET2000 has an Advance Programming Mode in order to set up
GB
GB
temperature lock and limit settings.
• Press the V button until the standby mode is reached.
DE
• The V button should then be released and then pressed and held
for a further 5 seconds to enter the Advanced Programming Mode.
DK
• To indicate that the unit is in Advanced Programming Mode the
Standby Indicator will flash and the display will show the setting
ES
number alternating with the current value for that setting.
• To change the setting press either the Λ or V button.
FR
• A simultaneous push and release of both buttons will scroll
through the steps S1 to S3 and will save the current set value if
altered.
NL
• To exit Advanced Programming Mode and return to Standby
Mode press and hold both buttons for more than 5 seconds.
RU
• While in Advanced Programming Mode if no buttons are pressed
for more than 2 minutes the unit will automatically return to
TR
Standby mode, and the value on the current setting will not be
saved.