Herunterladen Inhalt Inhalt Diese Seite drucken
S+S REGELTECHNIK THERMASGARF ALTM1 Bedienungs- Und Montageanleitung

S+S REGELTECHNIK THERMASGARF ALTM1 Bedienungs- Und Montageanleitung

Anlegte-temperaturmessumformer incl. spannband, kaibrierfahig mit mehrbereichsumschaltung und aktivem ausgang

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

D G F r
6000-2720-0000-1XX 27200-2020 V104 03 ⁄ 2020
THERMASGARD
® 
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Anlegetemperaturmessumformer ⁄ Rohranlegefühler,
incl. Spannband, kalibrierfähig,
mit Mehrbereichsumschaltung und aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Surface contact ⁄ tube contact temperature measuring transducers,
including strap, calibratable,
with multi-range switching and active output
F
Notice d'instruction
Sonde de température d'applique pour conduites avec convertisseur,
y compris collier de serrage, étalonnable,
avec commutation multi-gamme et sortie active
r
Руководство по монтажу и обслуживанию
Датчик температуры накладной ⁄ накладной для труб,
вкл. хомут, калибруемый, с переключением между несколькими
диапазонами и активным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
ALTM 1
ALTM 2
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
ALTM 1

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für S+S REGELTECHNIK THERMASGARF ALTM1

  • Seite 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Seite 2 D G F r ALTM 1 THERMASGARD ®  Maßzeichnung ALTM 1 Dimensional drawing Plan coté Габаритный чертеж M12-Steckverbinder (optional auf Anfrage) M12 connector (optional on request) connecteur M12 (en option et sur demande) разъем M12 (опционально по запросу) ohne Display M16x1.5 without display sans écran...
  • Seite 3: Technische Daten

    ® THERMASGARD ALTM Rev. 2020 - V16 Kalibrierfähiger Anlegetemperaturmessumformer THERMASGARD ® ALTM 1 (Kompaktvariante) und ALTM 2 (abgesetzte Variante) mit acht umschaltbaren Messbereichen, stetigem Ausgang, im schlagfesten Kunststoffgehäuse mit Schnellverschlussschrauben, wahl weise mit ⁄ ohne Display, Kabelfühler mit Rohranleger (ALTM 2), incl. Spannband. Der Anlegefühler dient zur Erfassung der Temperatur an Leitungen, Rohren (z.B.
  • Seite 4 Messumformer, kalibrierfähig, mit aktivem Ausgang Bürdendiagramm TEMPERATURBEREICHE: Bürdendiagramm Bei der Auswahl der Messumformerbereiche ist 4...20 mA darauf zu achten, dass die höchstzulässige Temperatur des Fühlers ⁄ Gehäuses nicht über schritten wird ! Umgebungstemperatur für den Messumformer: – 30 ...+ 70 °C zulässiger Bürdenwiderstand = siehe Bürdendiagramm Bereich...
  • Seite 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der ANSCHLUSSBEDINGUNGEN Anschluss der Geräte darf nur an Sicherheitskleinspannung er folgen. Ausgang: 0 -10 V Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind von Die Ausgangsspannung folgt linear den am Eingang anliegenden Tempera- der Gewährleistung und Haftung ausgeschlossen.
  • Seite 6: Technical Data

    ® THERMASGARD ALTM Rev. 2020 - V16 Calibratable surface-contact temperature measuring transducer THERMASGARD ® ALTM 1 (compact variant) and ALTM 2 (detached variant) with eight switchable measuring ranges, continuous output, in an impact-resistant plastic housing with quick-locking screws, optionally with ⁄ without display, cable sensor with a pipe feeder (ALTM 2), incl.
  • Seite 7 Measuring transducers, calibrateable, with active output Load resistance diagram TEMPERATURE RANGES: Load resistance diagram When selecting measuring transducer ranges, 4...20 mA it is necessary to ensure that the maximum temperatures permissible for sensor ⁄ housing are not exceeded ! Ambient temperature for measuring transducers: –...
  • Seite 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must CONNECTING CONDITIONS only be connected to safety extra-low voltage. Consequential damages Output: 0 - 10 V caused by a fault in this device are excluded from warranty or liability. The output voltage follows linear to the temperature signal applied at These devices must be installed and commissioned by authorised the input terminals and generates a proportional output signal of 0 - 10 V.
  • Seite 9: Caractéristiques Techniques

    ® THERMASGARD ALTM Rev. 2020 - V16 Convertisseur de mesure de température d’applique étalonnable THERMASGARD ® ALTM 1 (version compacte) et ALTM 2 (version à épaulement), huit plages de mesure commutables, sortie analogique, boîtier en plastique résistant aux chocs avec vis de fermeture rapide, au choix avec / sans écran, sonde à...
  • Seite 10 Convertisseur de mesure étalonnable avec sortie active Load resistance diagram PLAGES DE TEMPÉRATURE (TB): Diagramme de charge Lors de la sélection des plages de convertisseur, 4...20 mA il faut veiller à ce que la température maximale admissible de la sonde ⁄ du boîtier ne soit pas dépassée ! Température ambiante du convertisseur: –...
  • Seite 11 Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. CONDITIONS DE RACCORDEMENT Veillez à ne brancher l’appareil que sur un réseau de très basse tension Sortie: 0 -10 V de sécurité. Nous déclinons toute responsabilité ou garantie au titre de La tension de sortie est linéaire en fonction du signal de température tout dommage consécutif provoqué...
  • Seite 12: Технические Данные

    ® THERMASGARD ALTM Rev. 2020 - V16 Калибруемый накладной измерительный преобразователь температуры THERMASGARD ® ALTM 1 (компактное исполнение) и ALTM 2 (выносное исполнение) с 8 переключаемыми диапазонами измерения, аналоговым выходом, в ударопрочном пластиковом корпусе с быстрозавора- чиваемыми винтами, на выбор с дисплеем или без дисплея, накладной кабельный датчик, вкл. стяжной хомут. Предназначен...
  • Seite 13: Напряжение Питания

    Преобразователи измерительные, калибруемые, с активным выходом Load resistance diagram ТЕМПЕРАТУРНЫЕ ДИАПАЗОНЫ: Нагрузочная диаграмма При выборе диапазона для измерительного преобразователя 4...20 мA следует учитывать, что не разрешается превышение максимальной допустимой температуры датчика  ⁄ корпуса ! Температура окружающей среды для измерительного преобразователя: –...
  • Seite 14: Условия Подключения

    Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подключение УСЛОВИЯ ПОДКЛЮЧЕНИЯ должно осуществляться исключительно к безопасно малому напряжению. Выход: 0 - 10 В Повреждения приборов вследствие несоблюдения упомянутых требований Выходное напряжение линейно зависит от сигнала температуры на не...
  • Seite 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Seite 16 D G F r ALTM 1 THERMASGARD ®  ALTM 2 THERMASGARD ®  Anschlussbild ALTM - U Anschlussbild * ALTM - I DIP-Schalter DIP-Schalter Kontakt- Kontakt- Messbereichs- Messbereichs- seite seite umschaltung umschaltung 1 2 3 1 2 3 interner Sensor interner Sensor min.

Diese Anleitung auch für:

Thermasgarf altm2

Inhaltsverzeichnis