Herunterladen Inhalt Inhalt Diese Seite drucken

Replacement Parts; Environment And Recycling - Grohe Blue Serie Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Blue Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Service
Note the Fault/ Cause/ Remedy table for information on
eliminating problems.
If the problem cannot be rectified, interrupt the power supply
to the cooler/carbonator. Note down the serial number of the
cooler/carbonator on the rear of the device and consult
a specialist installer or contact the GROHE Service Hotline
via email under TechnicalSupport-HQ@grohe.com.
®
The GROHE Blue
Chilled & Sparkling cooler/carbonator
may only be repaired by GROHE Service.

Replacement parts

See fold-out page I (* = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Fault
Cause
Water not flowing
• Water supply interrupted
Filtered water not
• Water supply interrupted
flowing, E1 flashes
• Pump switched off, display in handle
in the display
flashes red
Filtered water is
• Safety shut-off of solenoid valve for
interrupted, E2
running time of over 4 minutes
flashes in the display
Filtered water does
• Cable or connector faulty
not flow, E3 or E4
flashes in the display
Handle flashes
• No filter capacity
orange, E8 flashes
in the display
E5, E6, E7 or EE
• Fault in cooler/carbonator
flashes in the display
Splashy, irregular
• CO
flow
Indicator lamps
• Control not recognised
do not flash/flash
continuously
No carbon dioxide in
• CO
positions Medium
and Sparkling
content of water set incorrectly
2
cylinder not opened or empty
2

Environment and recycling

Used filter cartridges can be returned to GROHE at the
address for the relevant country, at www.grohe.com.
However, the filter can also be disposed of hazard-free in
domestic waste.
The accompanying CO
cylinder can be refilled locally.
2
The CO
cylinder must not be sent back. At the end of its
2
useful life it must be disposed of locally in accordance with the
applicable regulations.
Note: A 2 kg CO
cylinder (Prod. no: 40 423) can be ordered
2
at www.grohe.com.
The cooler/carbonator is an electrical device, to which return
and take-back obligations apply in many countries. GROHE
participates in such take-back systems in all relevant
countries.
This category of device does not belong in
the domestic waste, but must be disposed of
separately in accordance with the relevant
local national regulations.
Remedy
- Open shut-off valves
- Establish water supply to cooler/carbonator
- Disconnect the power supply, wait 15 seconds
and re-connect.
- Close handle and open it again.
- Contact Grohe Service
- Change filter cartridge immediately
- Contact Grohe Service
- Contact Grohe Service
- Connect mains supply, disconnect plug-in
connector, wait 30 seconds and reconnect
- Fully open valve of CO
cylinder
cylinder or replace
2
8

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

31 32331 32431 33931 340

Inhaltsverzeichnis