A / SPECIFICATIONS
- Operates with the RAIN BIRD TBOS latching
solenoid.
- 3 independent programs (A, B, C) with up to 8
start times per day and per program.
Stations can be assigned to several programs
with different watering run time.
- Watering time from 1 minute to 12 hours per station.
- Watering cycle: customized cycle (7 days),
even, odd, odd-31 (no watering on 31), cyclical.
- Manual watering capabilities.
- Program level and global Monthly Seasonal
Adjust (0 à 300%).
- Rain Delay (1 to 14 days).
- Watering programs backup.
- Station names capabilities.
- Master Valve connection (not available on
1-station module).
- Sensor connection (Rain sensor or Flow sensor).
- Infrared transmission: the connection to the
control module and programming is possible
even if the module is submerged in water.
- Option: Radio connection with addition of a
TBOS-II
Radio Adaptor.
TM
- Operating temperature range: 14°F to 149°F.
- Operating pressure: up to 10 Bars.
See TBOS-II Field Transmitter instruction
Manual for set-up and program.
B / 9V BATTERY INSTALLATION
(not included)
See diagram 2
- Powered by a new 9V alkaline battery type
6AM6 (international standard) or 6LR61
'(European standard) - Top quality brands
recommended : Varta or equivalent.
Battery not included.
- Low battery icon displays on TBOS-II
Field Transmitter (necessary after battery
replacement).
C / SOLENOID INSTALLATION
See diagrams 5 - 6
1 - Mounting the solenoid on the valve: remove
the existing solenoid on the valve and replace it
with the latching solenoid.
Gently screw it hand-tight.
2 - Connect the latching solenoid to the control
module. Use the Rain Bird Quick Connect «King»
wire connectors supplied with the module.
Important : the wire run between the control
module and the solenoid must not exceed 10 m
using 0.75 mm² wire.
Check the system by using the manual start
function. If the system does not turn on, screw
the solenoid a little tighter to the valve.
D / MAINTENANCE
- Replace the 9V battery (alkaline : type 6LR61
or equivalent) once a year.
- Make sure that the optical connector is clean
when the connection is made.
Use water to clean it if needed.
E / DECLARATION OF CONFORMITY
TO EUROPEAN DIRECTIVES
- The device shall be placed on a closed valve
box, isolated from UV.
- IP68 sealing.