Herunterladen Inhalt Inhalt Diese Seite drucken

SSS Siedle ATLC/NG 670-0 Produktinformation Seite 4

Vorschau ausblenden Andere Handbücher für ATLC/NG 670-0:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
Application
Access door loudspeaker controller
with line rectifier in switch panel
housing as an interface for the
connection and power supply of
door components to the Access
Professional network.
Application
The combination of ATLC 670-...
with ANG 600-... can only be used
in connection with Siedle Access.
The devices are used for connection
and power supply to the door sta-
tion and/or the assigned camera.
Any other application is deemed not
in accordance with its intended use
and exonerates the manufacturer
from any liability.
Electrical voltage
• Mounting, installation and
servicing work on electrical devices
may only be performed by a suitably
qualified electrician. Failure to
observe this regulation could result
in the risk of serious damage to
health or fatal injury due to electric
shocks.
• Operation at an altitude of up to
2000 m above sea level.
• Observe EN 62368-1!
In a building installation, an all-
pole mains switch with a contact
opening of at least 3 mm must be
provided. The device must not be
exposed to water drops or sprayed
water! Sufficient ventilation must be
ensured. Pay particular attention to
ensure that ventilation slots are not
covered.
• When using stranded cores as
cable material, these must be fitted
with wire end ferrules without fail.
Scope of supply
ATLC/NG 670-... comprises:
• ATLC 670-... Access door loud-
speaker controller for top hat rail
mounting
• ANG 600-... Access line rectifier
for top hat rail mounting
• This product information
4
Mounting
The two devices ATLC 670-... and
ANG 600-... are connected using
the provided ribbon cable prior to
mounting.
1 Clip the two devices onto the top
hat rail.
Terminal assignment
ATLC 670-...
S1
Power supply and audio
S2
transmission
S3
S4
D1
Data transmission with
D2
digital call and Vario bus
data transmission
V1
Video signal
V2
(two-wire FBAS)
15
input via potential-free
16
contact
E
or
17
input galvanically isolated
18
4-30 V DC, 10 mA
13
switching contact
14 A2
30 V AC/DC, 2 A e.g. for
light contact
23
output (door release)
24
AC/DC programmable
A1
10-16 V AC max. 700 mA,
13 V DC max. 300 mA
ANG 600-...
L
100–240 V AC, +/–10 %,
N
50/60 Hz
PE
not assigned
+
Output voltage 48 V DC,
-
800 mA
11
changeover contact 250 V
12
A3
6 A, circuit breaker with
14
max. 10 A
Installation and commissioning
The Access commissioning instruc-
tions and the Access planning and
system manual can be found in the
Siedle download area.
Specification of the changeover
contact
• Contact load at least
5 V, 100 mA
10 V, 10 mA
24 V, 1 mA
• Admissible switching outputs:
Motor max. 3 A
bulbs max. 1300 W
Energy saving lamps max.
18 x Silvania 7 W or
12 x Osram 11 W
Fluorescent lamps uncompensated
cos j 0.5 max. 800 VA
Duo fluorescent lamps
max. 1200 VA
Parallel compensated fluorescent
lamps max. 400 VA
Iron core transformers for low-
voltage halogen lamps max. 1000 W
Electronic transformers for low-
voltage halogen lamps max. 1300 W
Specifications ANG 600-...
Operating voltage: 100–240 V AC,
+/-10 %, 50/60 Hz
Operating current: 0.5–1 A
Output voltage: 48 V DC
Output current: 800 mA
Fusing: primary T 2 A, secondary
short circuit proof
Contact type: changeover switch
max. 250 V AC, 6 A
Protection system: IP 20
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 6
Dimensions (mm) W x H x D:
107 x 89 x 60
Specifications ATLC 670-...
Output voltage: 10–16 V AC/DC
Output current:
max. 700 mA AC/300 mA DC
Contact type: Contact 30 V, 2 A
Protection system: IP 20
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 6
Dimensions (mm) W x H x D:
107 x 89 x 60

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis