Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation - Duravit St.Trop Montageanleitung

Dampfdusche (vorwand)
Vorschau ausblenden Andere Handbücher für St.Trop:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4

Electrical installation

Power supply
Max. nominal output
Fuse protection
RCD
Pre-installation
> Installing a permanent power supply line:
Pre-connect a separate fuse and
residual current operating device (RCD)
Pre-connect an all-pole separating main switch
outside the prescribed safety areas (0 - 2)
Allow the supply line to protrude by 3,000 mm
> Laying the potential equalisation cable:
Allow the cable to protrude by 3,000 mm
38
Connecting the steam shower (Diagram 38)
ADVICE! Providing for maintenance on the technical unit.
> Lay the cable loop in such a way that the technical
unit can be pulled out without any problems.
I
Connect the supply line to the mains supply
socket.
II
Connect the potential equalisation of the house
and the potential equalisation supplied for the
47
control
to rails.
III
ADVICE! Avoiding any malfunctions!
> Keep cables away from hot pipes that are
carrying steam.
> Fasten the cables together with cable ties.
Safety areas in accordance with DIN VDE 0100-701
0
6 0
1
0
6 0
0
2
3
* or the height of
the highest shower
head / water outlet
that is permanently
installed; depending
on which is higher
220 - 240 V~, 50/60 Hz
3,1 kW
I
= 16 A
N
I
≤ 30 mA
ΔN
I
PE
N
L
II
III
7
DD_M_St.Trop_VW/13.02.7