Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
Enough time has passed for products to be cooled
Ventilation holes of the device are not blocked
(This concerns the "IGLOO" thermostat) thermostat displays C0 or C1 or C2 instead of displaying temperature:
This situation shall occur, when one of temperature regulation sensors has been destroyed. The following
messages may be displayed in such case:
C0 – temperature sensors inside the chamber are damaged – call authorized service
C1 – failure of evaporator sensor - call authorized service
C2 – failure of condenser alarm sensors (or failure of second evaporator sensor) – call authorized service
(This concerns the "CAREL" thermostat) Thermostat displays E0 or E1 or L0 or HI or EE or Ed or DF instead
of temperature:
E0 – failure of temperature sensor inside the chamber – call authorized service
E1 – failure of evaporator sensor – call authorized service
L0 – low temperature alarm (lower than temperature range set within the device – call authorized service
HI – high temperature alarm – call authorized service
EE – internal defect of the regulator – call authorized service
Ed – max. defrosting time exceeded
DF – defrosting in progress (this is not an alarm signal)
(This concerns the "IGLOO" thermostat) The device is working, sound signalling is activated...– Make sure that:
The condenser is clean, if necessary – clean the condenser
Condenser ventilator is working properly
Ambient temperature does not exceed 25ºC
The device is working too loud...– Make sure that:
The device is standing stably and is properly levelled
Furniture adjoining the device do not vibrate when the cooling aggregate compressor is working
Noises made by the operating device are a normal phenomenon. The devices are equipped with ventilators,
engines and compressors, which turn on and off automatically. Each compressor makes certain noises
when operating. These sounds are made by the aggregate engine and by cooling agent flowing thro-
ugh the circuit. This phenomenon constitutes a technical feature of cooling devices and it does not
signify their faulty work.
Steam precipitation on glasses of the device is a normal phenomenon in case of high relative air humidity
exceeding 60% and does not require calling the service

6.2. Service

IGLOO service telephone number: +48 (14) 662 19 56 or +48 605 606 071 e-mail: serwis@igloo.pl
If after checking points described in chapter 6.1 "Fault identification and repair" the device still does not work
properly, please contact Technical Service of the Igloo company, stating the data from the data plate Fig.13 (p.10)
Fig.12 Data plate
The data plate is located inside the device, on the screen, in its right upper corner
www.igloo.pl
• Serial number (NS)
• Production date
• Type (name of the device)
and
• Date when the device was purchased
• Description of the problem
• Your exact address and telephone number
(with the code number)
en
19
User manual BALI

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis