Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

units and work surfaces that align to the
standards.

8.3 Connection cable

• The hob is supplied with the
connection cable.
• Replace the damaged mains cable
only with the spare parts cable. Speak
to your local Authorised Service
Center.
WARNING!
All electrical connections
must be made by a qualified
electrician.
CAUTION!
Do not drill or solder the
wire ends. This is strictly
forbidden!
230V~
N
L
One-phase connection - 230 V~
N
L
Green - yellow
Blue and grey
Black and brown
CAUTION!
Do not connect the cable
without cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from
black and brown wires.
2. Remove an insulation of the brown
and black cable ends.
3. Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
Cable cross section
400V 2~N
Two-phase connection - 400 V 2 ~ N
Green - yellow
Blue and grey
Black
Brown
ENGLISH
17
N
L1
L2
N
L1
L2