WARNINGS FOR THE EVERYDAY USE
OF THE AUTOMATION

7.1 - "Obstacle detection" function

Era Star A is equipped with an "Obstacle detection" safety system that guarantees
the good condition of the shutter: it is activated when the shutter movement (ascent
or descent) is suddenly stopped by an obstacle (object, person, etc.) or a high level
of friction (formation of ice, material expansion, etc.). In these cases the control unit
immediately blocks the movement.
7.2 - Maximum continuous work cycle
In general, the motors of the "Era" range are designed for residential applications
and therefore for discontinuous use. They guarantee a maximum continuous operat-
ing time of 4 minutes; in the event of overheating (for example due to continuous and
prolonged operation), a "thermal cut-out" trips automatically to shut off power sup-
ply. Power is only restored when the temperature returns to within the normal range.
7.3 - "Limit switch auto-update" function
Caution! – This function is active only if the limit switch has been programmed with
the "Automatic mode" or "Semi-automatic mode" procedure. During daily use of the
automation, the impact of the shutter against the travel limit at the end of a manoeu-
vre is due to the "Limit switch auto-update function" which measures the parameters
of the two limit switch positions and updates the values previously memorised. The
aim of this function is to compensate over time any expansion or shrinkage of the
structure (due to wear or temperature variations) thus allowing the Ascent and De-
scent movements to stop precisely at their respective travel limits.
What to do if
(troubleshooting guide)
q The electric phase is powered but the motor does not move:
If the thermal cut-out has tripped simply wait for the motor to cool. If this is not
the case check that the mains voltage corresponds to the data shown in the
specifications in this manual; to do this measure the voltage between the "com-
mon" wire and the one of the powered electric phase. Finally try to power the op-
posite electric phase.
q The ascent command is given but the motor does not start:
If the shutter is already closed or almost closed the motor does not perform the
ascent manoeuvre. In this case the shutter must be moved down slightly and
then the ascent command can be given again.
q The system operates in the hold-to-run emergency mode:
– Check if the motor has been subjected to significant electric or mechanical
shock.
– Check that each part of the motor is in good condition.
– Perform the deletion procedure (paragraph 6.5) and programme the limit
switches again.
q Involuntary stop of the shutter movement (false obstacle):
Once the command has been given to the shutter, if its stops in a certain point for
no apparent reason (false obstacle) proceed as follows:
– adjust the obstacle detection sensitivity level (paragraph 6.4), increasing the
force.
If this is not sufficient,
– delete the limit switches (paragraph 6.5) and program them again using only
the procedure B - "Secondary procedure" (paragraph 6.2).
...
Product disposal
As in installation, also at the end of product lifetime, the disassembly and scrapping
operations must be performed by qualified personnel.
This product is made of various types of material, some of which can be recycled
while others must be scrapped. Seek information on the recycling and disposal sys-
tems envisaged by the local regulations in your area for this product category. Cau-
tion! – some parts of the product may contain pollutant or hazardous substances
which, if disposed of into the environment, may cause serious damage to the envi-
ronment or physical health. As indicated by the symbol alongside, dis-
posal of this product in domestic waste is strictly prohibited. Separate
the waste into categories for disposal, according to the methods en-
visaged by current legislation in your area, or return the product to the
retailer when purchasing a new version. Caution! – Local legislation
may envisage serious fines in the event of abusive disposal of this product.
• The product's packaging materials must be disposed of in full compliance with lo-
cal regulations.
Technical specifications
l Power supply voltage: see data on rating plate
l Power absorbed in Stand-by mode: 0,5 W
l Encoder resolution: 2,7°
l Continuous operating time: 4 minutes
l Connection cable length: 2.5 m
l Minimum operating temperature: -20 °C
l Protection rating: IP 44
Notes:
– All technical specifications refer to an ambient temperature of 20°C (± 5°C).
– Nice S.p.a. reserves the right to apply modifications to the product at any time
when deemed necessary, while maintaining the same functionalities and in-
tended use.
CE declaration of conformity
Declaration number: 401/E STAR A
Nice S.p.A. hereby declares that the products:
E Star SA 324
E Star MA 517
E Star MA 817
E Star SA 524
E Star SA 611
E Star MA 1517
E Star SA 1011
E Star MA 3017
comply with the essential requirements and other relevant provisions as established
by the directives 2006/95/EC, 2004/108/EC. The EC declaration of conformity can
be consulted and printed out at the web site www.nice-ser vice.it or may be requested
from Nice S.p.A.
E Star MA 4012
E Star LA 7517
E Star MA 5012
E Star LA 8012
E Star LA 5517
E Star LA 10012
E Star LA 6517
E Star LA 12012
Mr. Mauro Sordini
(Chief Executive Officer)
English – 6

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Era star a serieE star maE star la

Inhaltsverzeichnis