Herunterladen Diese Seite drucken

Installation - Elica Iceberg Montage- Und Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Iceberg:

Werbung

Warning!
— The hood cannot be connected to flues of
other appliances that run on energy
sources other than electricity.
— When the hood is used at the same time
of other appliances that run on energy
sources other than electricity, provision
must be made for an adequate supply of
air.
— No food must be cooked flambé
underneath the hood.
The use of an unprotected flame is
dangerous for the filters and could cause
fires.
Therefore, never use an open flame under
the hood. When frying foods, never leave
the pan alone because the cooking oil
could flare up.
— Please, keep to the provisions of official
directives regarding the question of fume
discharge.
— The manufacturers refuse to accept any
responsibility for damage to the hood or
its catching on fire because of failure to
observe the above instructions.

Installation

These minimum distances between hobs
and grease filter must be observed:
Minimum 600 mm - electric hobs
Minimum 700 mm - gas or mixed hobs
Do not tile, grout or silicone this appliance
to the wall. Surface mounting only.
Do not fix chimney flue to furniture or fly over
shelves unless the chimney flue can be
easily removed, in case maintenance is
ever required.
GB
Electric connection
Before completing any connection, make
sure the house voltage corresponds with
the voltage indicated on the label affixed
inside the hood
It is advisable to call a qualified technician
to make the electrical connection.
Appliance fitted with plug.
Connect it to a socket which conforms with
current regulations.
If you intend to connect it directly to the
electric mains, remove the plug and fit an
approved bipolar switch with a minimum
contact opening of no less than 3mm.
If the plug is not accessible once it has been
inserted in the socket, it will however be
necessary to fit an approved bipolar switch
with a minimum contact opening of no less
than 3mm.
Appliance without plug
Fit an approved plug or an approved bipolar
switch with a minimum contact opening of
not less than 3mm.
The manufacturers are not liable for any
problems caused by the user's failure to
observer the above instructions.
Systems available
Two systems are available:
Exhaust mode
Vapours are extracted outside through an
exhausting pipe that is affixed to the
connection ring above the hood.
Diameter of the exhausting pipe must be
equal to that of the connection ring.
Attention!
If the hood is supplied with carbon filter,
then it must be removed.
Recirculation mode
The air is filtered through a carbon filter and
recirculated into the room through the grid
on the higher part of the chimney.
Attention!
This hood is not supplied with the carbon
filter, so must be ordered separately
if required.
6

Werbung

loading