2.9

Troubleshooting

Observe the safety instructions and maintenance instructions!
Problem
A
No material or
insufficient mate-
rial sprayed
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
If necessary, contact our service staff, see last page.
II/ 10
Cause
Multi-purpose gun does not
draw in material
Spray nozzle (item 10) blocked
Working pressure (flow pres-
sure) too low
Compressor output too small
Hose diameter too small
Remedy
Adjust the spray nozzle (item 10)
until
the
multi-purpose
draws in material correctly
Clean spray nozzle (item 10) or
replace
Increase working pressure (flow
pressure)
Observe
working pressure
Use different output
*
rating
Use correct hose diameter
gun
maximum
*
*

Werbung