4. Applications
Areas of use:
For irrigating and watering parks, vegetable
patches and gardens
For operating lawn sprinklers
With a prefilter, for drawing water from ponds,
streams, rain-butts, rain-water cisterns and wells.
Media which can be pumped:
For the pumping of clear water (fresh water), rain
water or mild suds/dirty water.
5. Operating instructions
Basically, we recommend the use of a prefilter and
an intake set with an intake hose, an intake strainer
and check valve in order to prevent long repriming
times and any unnecessary damage to the pump
caused by stones and hard foreign bodies.

6. Technical data

Mains supply:
Power rating:
Delivery rate max.
Delivery height max.
Delivery pressure max.
Suction height max.
Delivery and intake connection:
Water temperature max.
Sound pressure level:
Sound power level:

7. Electrical connections

Connect the power cable to a 230 V 50 Hz
earthed, 10 amp fuse minimum.
The appliance is switched on and off using the
integrated ON/OFF switch.
The motor is protected against overloading or
blocking by an integrated thermostat. In the event
of overheating, the thermostat switches off the
pump automatically. The pump will start up again
automatically after it has cooled down.
8. Intake line
Screw an intake hose (min. 3/4" plastic hose with
spiral reinforcement) either directly or with a
threaded nipple to the pump's intake connection
(1" IG) (see Fig. 1).
The intake hose used should have an intake
valve. If the intake valve cannot be used, a check
valve should be installed in the intake line.
The intake hose should rise from the water pick-
up point to the pump. Always avoid laying the
intake line higher than the pump. Air bubbles in
the intake line delay and hinder suction.
The intake and pressure lines must be attached in
such a way that they do not place the pump under
any mechanical strain.
The intake valve should be so far immersed in the
water that the pump cannot run dry even if the
water level falls.
If the intake line is not air-tight, the intake of air
will hinder the intake of water.
Avoid drawing in foreign bodies (sand etc.).
If necessary, install a prefilter for this purpose.
230V ~ 50 Hz
600 W
2
3000 l/h
42 m
Intake line
4,2 bar
connection
8 m
1" IG
35°C
69 dB(A)
79,6 dB(A)
Pressure line
connection
GB