BTL6-V5 _ V-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
Installation
NOTICE!
Improper installation
Improper installation can compromise the function of the
transducer and result in damage.
► For this reason, ensure that no strong electrical or
magnetic fields are present in the immediate vicinity
of the transducer.
► The recommended spacing for the installation must
be strictly observed.
Any orientation is permitted. Mount the transducer on a
level surface of the machine using the provided mounting
clamps and cylinder-head screws. A sufficient number of
mounting clamps is supplied.
In order to avoid the development of resonant
frequencies from vibration loads, we
recommend arranging the mounting clamps at
irregular intervals.
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect transducer and controller using a shielded
cable.
Shielding: Braided copper shield with minimum 85%.
Shield is internally connected to connector housing.
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the transducer and strong, external magnetic
fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
Cable length
The maximum cable length when using CAT5e cables is
100 m.
Noise elimination
To avoid equipotential bonding - a current flow - through
the cable shield, please note the following:
Use insulating bushes
Put the control cabinet and the system in which the
BTL6 is located to the same ground potential.
www.balluff.com
The transducer is electrically isolated from the machine
with the supplied insulating bushes.
1. Guide the transducer into the mounting clamps.
2. Attach transducer to the base using mounting screws
(tighten screws in the clamps with max. 2 Nm).
3. Insert magnet (accessories).
The micropulse transducer in profile housing is
suitable both for floating, i.e. non-contacting
magnets.
If multiple magnets are used, the distance
between the magnets must be at least 65 mm.
Startup
DANGER
Uncontrolled system movement
When starting up, if the linear encoder is part of a closed
loop system whose parameters have not yet been set,
the system may perform uncontrolled movements. This
could result in personal injury and equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections or devices.
2. Turn on the system.
3. Check measured values in the controller and reset if
necessary.
Operating notes
Check the function of the position measuring system
and all associated components on a regular basis.
Take the position measuring system out of operation
whenever there is a malfunction.
Secure the system against unauthorized use.